ABAP Select data from SAP table /BIC/CCTA0CO_PC_PCP_30 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /BIC/CCTA0CO_PC_PCP_30 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /BIC/CCTA0CO_PC_PCP_30. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /BIC/CCTA0CO_PC_PCP_30 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/BIC/CCTA0CO_PC_PCP_30 TYPE STANDARD TABLE OF /BIC/CCTA0CO_PC_PCP_30,
      WA_/BIC/CCTA0CO_PC_PCP_30 TYPE /BIC/CCTA0CO_PC_PCP_30,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </BIC/CCTA0CO_PC_PCP_30> TYPE /BIC/CCTA0CO_PC_PCP_30.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/BIC/CCTA0CO_PC_PCP_30.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /BIC/CCTA0CO_PC_PCP_30
  INTO TABLE IT_/BIC/CCTA0CO_PC_PCP_30.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /BIC/CCTA0CO_PC_PCP_30
*  INTO TABLE @DATA(IT_/BIC/CCTA0CO_PC_PCP_302).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/BIC/CCTA0CO_PC_PCP_30 INDEX 1 INTO DATA(WA_/BIC/CCTA0CO_PC_PCP_302).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/BIC/CCTA0CO_PC_PCP_30 ASSIGNING </BIC/CCTA0CO_PC_PCP_30>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</BIC/CCTA0CO_PC_PCP_30>-KLVAR = 1.
</BIC/CCTA0CO_PC_PCP_30>-TVERS = 1.
</BIC/CCTA0CO_PC_PCP_30>-WERKS = 1.
</BIC/CCTA0CO_PC_PCP_30>-MATNR = 1.
</BIC/CCTA0CO_PC_PCP_30>-KADKY = 1.
ENDLOOP.

LOOP AT IT_/BIC/CCTA0CO_PC_PCP_30 INTO WA_/BIC/CCTA0CO_PC_PCP_30.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/BIC/CCTA0CO_PC_PCP_30-KADAT, sy-vline,
WA_/BIC/CCTA0CO_PC_PCP_30-BIDAT, sy-vline,
WA_/BIC/CCTA0CO_PC_PCP_30-FEH_STA, sy-vline,
WA_/BIC/CCTA0CO_PC_PCP_30-STUFE, sy-vline,
WA_/BIC/CCTA0CO_PC_PCP_30-KALNR, sy-vline,
WA_/BIC/CCTA0CO_PC_PCP_30-POSNR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/BIC/CCTA0CO_PC_PCP_30 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/BIC/CCTA0CO_PC_PCP_30 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/BIC/CCTA0CO_PC_PCP_30 INTO WA_/BIC/CCTA0CO_PC_PCP_30. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/BIC/CCTA0CO_PC_PCP_30_STR,
KLVAR TYPE STRING,
TVERS TYPE STRING,
WERKS TYPE STRING,
MATNR TYPE STRING,
KADKY TYPE STRING,
KADAT TYPE STRING,
BIDAT TYPE STRING,
FEH_STA TYPE STRING,
STUFE TYPE STRING,
KALNR TYPE STRING,
POSNR TYPE STRING,
TYPPS TYPE STRING,
RESOU TYPE STRING,
ELEMT TYPE STRING,
KSTAR TYPE STRING,
HRKFT TYPE STRING,
KOSTL TYPE STRING,
PRCTR TYPE STRING,
LSTAR TYPE STRING,
PWERK TYPE STRING,
PMATN TYPE STRING,
PMTAR TYPE STRING,
LIFNR TYPE STRING,
ARBPL TYPE STRING,
PRZNR TYPE STRING,
VORNR TYPE STRING,
INFNR TYPE STRING,
EKORG TYPE STRING,
STPOS TYPE STRING,
VALCG TYPE STRING,
VALCF TYPE STRING,
VALCV TYPE STRING,
PRECG TYPE STRING,
PRECF TYPE STRING,
PRECV TYPE STRING,
WAERS TYPE STRING,
MENGE TYPE STRING,
AUSMG TYPE STRING,
AUSMGKO TYPE STRING,
MEEHT TYPE STRING,
PMEHT TYPE STRING,
LTEXT TYPE STRING,
AUSME TYPE STRING,
AMENG TYPE STRING,
SCRAK_C TYPE STRING,
SCRAP_C TYPE STRING,
SICHT TYPE STRING,
KOKRS TYPE STRING,END OF T_EKKO_STR. DATA: WA_/BIC/CCTA0CO_PC_PCP_30_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/BIC/CCTA0CO_PC_PCP_30_STR-KLVAR sy-vline
WA_/BIC/CCTA0CO_PC_PCP_30_STR-TVERS sy-vline
WA_/BIC/CCTA0CO_PC_PCP_30_STR-WERKS sy-vline
WA_/BIC/CCTA0CO_PC_PCP_30_STR-MATNR sy-vline
WA_/BIC/CCTA0CO_PC_PCP_30_STR-KADKY sy-vline
WA_/BIC/CCTA0CO_PC_PCP_30_STR-KADAT sy-vline
WA_/BIC/CCTA0CO_PC_PCP_30_STR-BIDAT sy-vline
WA_/BIC/CCTA0CO_PC_PCP_30_STR-FEH_STA sy-vline
WA_/BIC/CCTA0CO_PC_PCP_30_STR-STUFE sy-vline
WA_/BIC/CCTA0CO_PC_PCP_30_STR-KALNR sy-vline
WA_/BIC/CCTA0CO_PC_PCP_30_STR-POSNR sy-vline
WA_/BIC/CCTA0CO_PC_PCP_30_STR-TYPPS sy-vline
WA_/BIC/CCTA0CO_PC_PCP_30_STR-RESOU sy-vline
WA_/BIC/CCTA0CO_PC_PCP_30_STR-ELEMT sy-vline
WA_/BIC/CCTA0CO_PC_PCP_30_STR-KSTAR sy-vline
WA_/BIC/CCTA0CO_PC_PCP_30_STR-HRKFT sy-vline
WA_/BIC/CCTA0CO_PC_PCP_30_STR-KOSTL sy-vline
WA_/BIC/CCTA0CO_PC_PCP_30_STR-PRCTR sy-vline
WA_/BIC/CCTA0CO_PC_PCP_30_STR-LSTAR sy-vline
WA_/BIC/CCTA0CO_PC_PCP_30_STR-PWERK sy-vline
WA_/BIC/CCTA0CO_PC_PCP_30_STR-PMATN sy-vline
WA_/BIC/CCTA0CO_PC_PCP_30_STR-PMTAR sy-vline
WA_/BIC/CCTA0CO_PC_PCP_30_STR-LIFNR sy-vline
WA_/BIC/CCTA0CO_PC_PCP_30_STR-ARBPL sy-vline
WA_/BIC/CCTA0CO_PC_PCP_30_STR-PRZNR sy-vline
WA_/BIC/CCTA0CO_PC_PCP_30_STR-VORNR sy-vline
WA_/BIC/CCTA0CO_PC_PCP_30_STR-INFNR sy-vline
WA_/BIC/CCTA0CO_PC_PCP_30_STR-EKORG sy-vline
WA_/BIC/CCTA0CO_PC_PCP_30_STR-STPOS sy-vline
WA_/BIC/CCTA0CO_PC_PCP_30_STR-VALCG sy-vline
WA_/BIC/CCTA0CO_PC_PCP_30_STR-VALCF sy-vline
WA_/BIC/CCTA0CO_PC_PCP_30_STR-VALCV sy-vline
WA_/BIC/CCTA0CO_PC_PCP_30_STR-PRECG sy-vline
WA_/BIC/CCTA0CO_PC_PCP_30_STR-PRECF sy-vline
WA_/BIC/CCTA0CO_PC_PCP_30_STR-PRECV sy-vline
WA_/BIC/CCTA0CO_PC_PCP_30_STR-WAERS sy-vline
WA_/BIC/CCTA0CO_PC_PCP_30_STR-MENGE sy-vline
WA_/BIC/CCTA0CO_PC_PCP_30_STR-AUSMG sy-vline
WA_/BIC/CCTA0CO_PC_PCP_30_STR-AUSMGKO sy-vline
WA_/BIC/CCTA0CO_PC_PCP_30_STR-MEEHT sy-vline
WA_/BIC/CCTA0CO_PC_PCP_30_STR-PMEHT sy-vline
WA_/BIC/CCTA0CO_PC_PCP_30_STR-LTEXT sy-vline
WA_/BIC/CCTA0CO_PC_PCP_30_STR-AUSME sy-vline
WA_/BIC/CCTA0CO_PC_PCP_30_STR-AMENG sy-vline
WA_/BIC/CCTA0CO_PC_PCP_30_STR-SCRAK_C sy-vline
WA_/BIC/CCTA0CO_PC_PCP_30_STR-SCRAP_C sy-vline
WA_/BIC/CCTA0CO_PC_PCP_30_STR-SICHT sy-vline
WA_/BIC/CCTA0CO_PC_PCP_30_STR-KOKRS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.