ABAP Select data from SAP table /BIC/CCTA0CO_PC_ACT_10 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /BIC/CCTA0CO_PC_ACT_10 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /BIC/CCTA0CO_PC_ACT_10. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /BIC/CCTA0CO_PC_ACT_10 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/BIC/CCTA0CO_PC_ACT_10 TYPE STANDARD TABLE OF /BIC/CCTA0CO_PC_ACT_10,
      WA_/BIC/CCTA0CO_PC_ACT_10 TYPE /BIC/CCTA0CO_PC_ACT_10,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </BIC/CCTA0CO_PC_ACT_10> TYPE /BIC/CCTA0CO_PC_ACT_10.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/BIC/CCTA0CO_PC_ACT_10.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /BIC/CCTA0CO_PC_ACT_10
  INTO TABLE IT_/BIC/CCTA0CO_PC_ACT_10.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /BIC/CCTA0CO_PC_ACT_10
*  INTO TABLE @DATA(IT_/BIC/CCTA0CO_PC_ACT_102).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/BIC/CCTA0CO_PC_ACT_10 INDEX 1 INTO DATA(WA_/BIC/CCTA0CO_PC_ACT_102).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/BIC/CCTA0CO_PC_ACT_10 ASSIGNING </BIC/CCTA0CO_PC_ACT_10>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</BIC/CCTA0CO_PC_ACT_10>-COMP_CODE = 1.
</BIC/CCTA0CO_PC_ACT_10>-PLANT = 1.
</BIC/CCTA0CO_PC_ACT_10>-MATERIAL = 1.
</BIC/CCTA0CO_PC_ACT_10>-VAL_TYPE = 1.
</BIC/CCTA0CO_PC_ACT_10>-VAL_CLASS = 1.
ENDLOOP.

LOOP AT IT_/BIC/CCTA0CO_PC_ACT_10 INTO WA_/BIC/CCTA0CO_PC_ACT_10.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/BIC/CCTA0CO_PC_ACT_10-STLMT_CTRL, sy-vline,
WA_/BIC/CCTA0CO_PC_ACT_10-DOC_NUMBER, sy-vline,
WA_/BIC/CCTA0CO_PC_ACT_10-S_ORD_ITEM, sy-vline,
WA_/BIC/CCTA0CO_PC_ACT_10-WBS_ELEMT, sy-vline,
WA_/BIC/CCTA0CO_PC_ACT_10-CATEG, sy-vline,
WA_/BIC/CCTA0CO_PC_ACT_10-PROCCATEG, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/BIC/CCTA0CO_PC_ACT_10 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/BIC/CCTA0CO_PC_ACT_10 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/BIC/CCTA0CO_PC_ACT_10 INTO WA_/BIC/CCTA0CO_PC_ACT_10. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/BIC/CCTA0CO_PC_ACT_10_STR,
COMP_CODE TYPE STRING,
PLANT TYPE STRING,
MATERIAL TYPE STRING,
VAL_TYPE TYPE STRING,
VAL_CLASS TYPE STRING,
STLMT_CTRL TYPE STRING,
DOC_NUMBER TYPE STRING,
S_ORD_ITEM TYPE STRING,
WBS_ELEMT TYPE STRING,
CATEG TYPE STRING,
PROCCATEG TYPE STRING,
CCOMPTYPE TYPE STRING,
ELESMHK TYPE STRING,
ELEMENT TYPE STRING,
STUFE TYPE STRING,
CURTYPE TYPE STRING,
VALUATION TYPE STRING,
FISCVARNT TYPE STRING,
FISCPER TYPE STRING,
CURRENCY TYPE STRING,
BASE_UOM TYPE STRING,
QUANTITY TYPE STRING,
PERVAL_F TYPE STRING,
PRCDIF_SF TYPE STRING,
PRCDIF_MF TYPE STRING,
EXRDIF_SF TYPE STRING,
EXRDIF_MF TYPE STRING,
PERVAL_V TYPE STRING,
PRCDIF_SV TYPE STRING,
PRCDIF_MV TYPE STRING,
EXRDIF_SV TYPE STRING,
EXRDIF_MV TYPE STRING,END OF T_EKKO_STR. DATA: WA_/BIC/CCTA0CO_PC_ACT_10_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/BIC/CCTA0CO_PC_ACT_10_STR-COMP_CODE sy-vline
WA_/BIC/CCTA0CO_PC_ACT_10_STR-PLANT sy-vline
WA_/BIC/CCTA0CO_PC_ACT_10_STR-MATERIAL sy-vline
WA_/BIC/CCTA0CO_PC_ACT_10_STR-VAL_TYPE sy-vline
WA_/BIC/CCTA0CO_PC_ACT_10_STR-VAL_CLASS sy-vline
WA_/BIC/CCTA0CO_PC_ACT_10_STR-STLMT_CTRL sy-vline
WA_/BIC/CCTA0CO_PC_ACT_10_STR-DOC_NUMBER sy-vline
WA_/BIC/CCTA0CO_PC_ACT_10_STR-S_ORD_ITEM sy-vline
WA_/BIC/CCTA0CO_PC_ACT_10_STR-WBS_ELEMT sy-vline
WA_/BIC/CCTA0CO_PC_ACT_10_STR-CATEG sy-vline
WA_/BIC/CCTA0CO_PC_ACT_10_STR-PROCCATEG sy-vline
WA_/BIC/CCTA0CO_PC_ACT_10_STR-CCOMPTYPE sy-vline
WA_/BIC/CCTA0CO_PC_ACT_10_STR-ELESMHK sy-vline
WA_/BIC/CCTA0CO_PC_ACT_10_STR-ELEMENT sy-vline
WA_/BIC/CCTA0CO_PC_ACT_10_STR-STUFE sy-vline
WA_/BIC/CCTA0CO_PC_ACT_10_STR-CURTYPE sy-vline
WA_/BIC/CCTA0CO_PC_ACT_10_STR-VALUATION sy-vline
WA_/BIC/CCTA0CO_PC_ACT_10_STR-FISCVARNT sy-vline
WA_/BIC/CCTA0CO_PC_ACT_10_STR-FISCPER sy-vline
WA_/BIC/CCTA0CO_PC_ACT_10_STR-CURRENCY sy-vline
WA_/BIC/CCTA0CO_PC_ACT_10_STR-BASE_UOM sy-vline
WA_/BIC/CCTA0CO_PC_ACT_10_STR-QUANTITY sy-vline
WA_/BIC/CCTA0CO_PC_ACT_10_STR-PERVAL_F sy-vline
WA_/BIC/CCTA0CO_PC_ACT_10_STR-PRCDIF_SF sy-vline
WA_/BIC/CCTA0CO_PC_ACT_10_STR-PRCDIF_MF sy-vline
WA_/BIC/CCTA0CO_PC_ACT_10_STR-EXRDIF_SF sy-vline
WA_/BIC/CCTA0CO_PC_ACT_10_STR-EXRDIF_MF sy-vline
WA_/BIC/CCTA0CO_PC_ACT_10_STR-PERVAL_V sy-vline
WA_/BIC/CCTA0CO_PC_ACT_10_STR-PRCDIF_SV sy-vline
WA_/BIC/CCTA0CO_PC_ACT_10_STR-PRCDIF_MV sy-vline
WA_/BIC/CCTA0CO_PC_ACT_10_STR-EXRDIF_SV sy-vline
WA_/BIC/CCTA0CO_PC_ACT_10_STR-EXRDIF_MV sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.