ABAP Select data from SAP table /BIC/CCTA0CLM_CCT_10 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /BIC/CCTA0CLM_CCT_10 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /BIC/CCTA0CLM_CCT_10. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /BIC/CCTA0CLM_CCT_10 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/BIC/CCTA0CLM_CCT_10 TYPE STANDARD TABLE OF /BIC/CCTA0CLM_CCT_10,
      WA_/BIC/CCTA0CLM_CCT_10 TYPE /BIC/CCTA0CLM_CCT_10,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </BIC/CCTA0CLM_CCT_10> TYPE /BIC/CCTA0CLM_CCT_10.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/BIC/CCTA0CLM_CCT_10.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /BIC/CCTA0CLM_CCT_10
  INTO TABLE IT_/BIC/CCTA0CLM_CCT_10.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /BIC/CCTA0CLM_CCT_10
*  INTO TABLE @DATA(IT_/BIC/CCTA0CLM_CCT_102).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/BIC/CCTA0CLM_CCT_10 INDEX 1 INTO DATA(WA_/BIC/CCTA0CLM_CCT_102).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/BIC/CCTA0CLM_CCT_10 ASSIGNING </BIC/CCTA0CLM_CCT_10>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</BIC/CCTA0CLM_CCT_10>-CCT_GUID = 1.
</BIC/CCTA0CLM_CCT_10>-CCT_DATE = 1.
</BIC/CCTA0CLM_CCT_10>-CCT_TIME = 1.
</BIC/CCTA0CLM_CCT_10>-CCT_RESULT = 1.
</BIC/CCTA0CLM_CCT_10>-CCT_TYPE = 1.
ENDLOOP.

LOOP AT IT_/BIC/CCTA0CLM_CCT_10 INTO WA_/BIC/CCTA0CLM_CCT_10.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/BIC/CCTA0CLM_CCT_10-CCT_DIRECTION, sy-vline,
WA_/BIC/CCTA0CLM_CCT_10-CCT_XREACHED, sy-vline,
WA_/BIC/CCTA0CLM_CCT_10-COLL_GROUP, sy-vline,
WA_/BIC/CCTA0CLM_CCT_10-COLL_SEGMENT, sy-vline,
WA_/BIC/CCTA0CLM_CCT_10-COLL_SPECIALIST, sy-vline,
WA_/BIC/CCTA0CLM_CCT_10-COLL_STRATEGY, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/BIC/CCTA0CLM_CCT_10 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/BIC/CCTA0CLM_CCT_10 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/BIC/CCTA0CLM_CCT_10 INTO WA_/BIC/CCTA0CLM_CCT_10. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/BIC/CCTA0CLM_CCT_10_STR,
CCT_GUID TYPE STRING,
CCT_DATE TYPE STRING,
CCT_TIME TYPE STRING,
CCT_RESULT TYPE STRING,
CCT_TYPE TYPE STRING,
CCT_DIRECTION TYPE STRING,
CCT_XREACHED TYPE STRING,
COLL_GROUP TYPE STRING,
COLL_SEGMENT TYPE STRING,
COLL_SPECIALIST TYPE STRING,
COLL_STRATEGY TYPE STRING,
STRATEGY_VERSION TYPE STRING,
CUSTOMER TYPE STRING,
FIN_LOGSYS TYPE STRING,
PARTNER TYPE STRING,
CCT_NAME TYPE STRING,
CCT_COUNT TYPE STRING,
CCT_ITEM_TYPE TYPE STRING,
P2P_GUID TYPE STRING,
PROMISED_AMOUNT TYPE STRING,
PROMISED_CURR TYPE STRING,
P2P_COUNT TYPE STRING,
DISP_GUID TYPE STRING,
DISPUTED_AMOUNT TYPE STRING,
DISPUTED_CURR TYPE STRING,
DISP_COUNT TYPE STRING,
RSM_COUNT TYPE STRING,
WORKITEM_ID TYPE STRING,
LOGSYS TYPE STRING,END OF T_EKKO_STR. DATA: WA_/BIC/CCTA0CLM_CCT_10_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/BIC/CCTA0CLM_CCT_10_STR-CCT_GUID sy-vline
WA_/BIC/CCTA0CLM_CCT_10_STR-CCT_DATE sy-vline
WA_/BIC/CCTA0CLM_CCT_10_STR-CCT_TIME sy-vline
WA_/BIC/CCTA0CLM_CCT_10_STR-CCT_RESULT sy-vline
WA_/BIC/CCTA0CLM_CCT_10_STR-CCT_TYPE sy-vline
WA_/BIC/CCTA0CLM_CCT_10_STR-CCT_DIRECTION sy-vline
WA_/BIC/CCTA0CLM_CCT_10_STR-CCT_XREACHED sy-vline
WA_/BIC/CCTA0CLM_CCT_10_STR-COLL_GROUP sy-vline
WA_/BIC/CCTA0CLM_CCT_10_STR-COLL_SEGMENT sy-vline
WA_/BIC/CCTA0CLM_CCT_10_STR-COLL_SPECIALIST sy-vline
WA_/BIC/CCTA0CLM_CCT_10_STR-COLL_STRATEGY sy-vline
WA_/BIC/CCTA0CLM_CCT_10_STR-STRATEGY_VERSION sy-vline
WA_/BIC/CCTA0CLM_CCT_10_STR-CUSTOMER sy-vline
WA_/BIC/CCTA0CLM_CCT_10_STR-FIN_LOGSYS sy-vline
WA_/BIC/CCTA0CLM_CCT_10_STR-PARTNER sy-vline
WA_/BIC/CCTA0CLM_CCT_10_STR-CCT_NAME sy-vline
WA_/BIC/CCTA0CLM_CCT_10_STR-CCT_COUNT sy-vline
WA_/BIC/CCTA0CLM_CCT_10_STR-CCT_ITEM_TYPE sy-vline
WA_/BIC/CCTA0CLM_CCT_10_STR-P2P_GUID sy-vline
WA_/BIC/CCTA0CLM_CCT_10_STR-PROMISED_AMOUNT sy-vline
WA_/BIC/CCTA0CLM_CCT_10_STR-PROMISED_CURR sy-vline
WA_/BIC/CCTA0CLM_CCT_10_STR-P2P_COUNT sy-vline
WA_/BIC/CCTA0CLM_CCT_10_STR-DISP_GUID sy-vline
WA_/BIC/CCTA0CLM_CCT_10_STR-DISPUTED_AMOUNT sy-vline
WA_/BIC/CCTA0CLM_CCT_10_STR-DISPUTED_CURR sy-vline
WA_/BIC/CCTA0CLM_CCT_10_STR-DISP_COUNT sy-vline
WA_/BIC/CCTA0CLM_CCT_10_STR-RSM_COUNT sy-vline
WA_/BIC/CCTA0CLM_CCT_10_STR-WORKITEM_ID sy-vline
WA_/BIC/CCTA0CLM_CCT_10_STR-LOGSYS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.