ABAP Select data from SAP table /BIC/CCDB0EC_PCA_1 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /BIC/CCDB0EC_PCA_1 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /BIC/CCDB0EC_PCA_1. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /BIC/CCDB0EC_PCA_1 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/BIC/CCDB0EC_PCA_1 TYPE STANDARD TABLE OF /BIC/CCDB0EC_PCA_1,
      WA_/BIC/CCDB0EC_PCA_1 TYPE /BIC/CCDB0EC_PCA_1,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </BIC/CCDB0EC_PCA_1> TYPE /BIC/CCDB0EC_PCA_1.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/BIC/CCDB0EC_PCA_1.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /BIC/CCDB0EC_PCA_1
  INTO TABLE IT_/BIC/CCDB0EC_PCA_1.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /BIC/CCDB0EC_PCA_1
*  INTO TABLE @DATA(IT_/BIC/CCDB0EC_PCA_12).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/BIC/CCDB0EC_PCA_1 INDEX 1 INTO DATA(WA_/BIC/CCDB0EC_PCA_12).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/BIC/CCDB0EC_PCA_1 ASSIGNING </BIC/CCDB0EC_PCA_1>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</BIC/CCDB0EC_PCA_1>-FISCVAR = 1.
</BIC/CCDB0EC_PCA_1>-FISCPER = 1.
</BIC/CCDB0EC_PCA_1>-CHARTACCTS = 1.
</BIC/CCDB0EC_PCA_1>-KOKRS = 1.
</BIC/CCDB0EC_PCA_1>-RPRCTR = 1.
ENDLOOP.

LOOP AT IT_/BIC/CCDB0EC_PCA_1 INTO WA_/BIC/CCDB0EC_PCA_1.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/BIC/CCDB0EC_PCA_1-SPRCTR, sy-vline,
WA_/BIC/CCDB0EC_PCA_1-EPRCTR, sy-vline,
WA_/BIC/CCDB0EC_PCA_1-RACCT, sy-vline,
WA_/BIC/CCDB0EC_PCA_1-RBUKRS, sy-vline,
WA_/BIC/CCDB0EC_PCA_1-SBUKRS, sy-vline,
WA_/BIC/CCDB0EC_PCA_1-RFAREA, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/BIC/CCDB0EC_PCA_1 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/BIC/CCDB0EC_PCA_1 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/BIC/CCDB0EC_PCA_1 INTO WA_/BIC/CCDB0EC_PCA_1. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/BIC/CCDB0EC_PCA_1_STR,
FISCVAR TYPE STRING,
FISCPER TYPE STRING,
CHARTACCTS TYPE STRING,
KOKRS TYPE STRING,
RPRCTR TYPE STRING,
SPRCTR TYPE STRING,
EPRCTR TYPE STRING,
RACCT TYPE STRING,
RBUKRS TYPE STRING,
SBUKRS TYPE STRING,
RFAREA TYPE STRING,
SFAREA TYPE STRING,
RHOART TYPE STRING,
SHOART TYPE STRING,
RASSC TYPE STRING,
AFABE TYPE STRING,
VERSA TYPE STRING,
WERKS TYPE STRING,
REP_MATNR TYPE STRING,
RSCOPE TYPE STRING,
RMVCT TYPE STRING,
VALUETYPE TYPE STRING,
VALUTYP TYPE STRING,
RVERS TYPE STRING,
BALANCE TYPE STRING,
DEBIT TYPE STRING,
CREDIT TYPE STRING,
TURNOVER TYPE STRING,
CURTYPE TYPE STRING,
CURRUNIT TYPE STRING,
QUANTITY TYPE STRING,
QUANUNIT TYPE STRING,
UPMOD TYPE STRING,END OF T_EKKO_STR. DATA: WA_/BIC/CCDB0EC_PCA_1_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/BIC/CCDB0EC_PCA_1_STR-FISCVAR sy-vline
WA_/BIC/CCDB0EC_PCA_1_STR-FISCPER sy-vline
WA_/BIC/CCDB0EC_PCA_1_STR-CHARTACCTS sy-vline
WA_/BIC/CCDB0EC_PCA_1_STR-KOKRS sy-vline
WA_/BIC/CCDB0EC_PCA_1_STR-RPRCTR sy-vline
WA_/BIC/CCDB0EC_PCA_1_STR-SPRCTR sy-vline
WA_/BIC/CCDB0EC_PCA_1_STR-EPRCTR sy-vline
WA_/BIC/CCDB0EC_PCA_1_STR-RACCT sy-vline
WA_/BIC/CCDB0EC_PCA_1_STR-RBUKRS sy-vline
WA_/BIC/CCDB0EC_PCA_1_STR-SBUKRS sy-vline
WA_/BIC/CCDB0EC_PCA_1_STR-RFAREA sy-vline
WA_/BIC/CCDB0EC_PCA_1_STR-SFAREA sy-vline
WA_/BIC/CCDB0EC_PCA_1_STR-RHOART sy-vline
WA_/BIC/CCDB0EC_PCA_1_STR-SHOART sy-vline
WA_/BIC/CCDB0EC_PCA_1_STR-RASSC sy-vline
WA_/BIC/CCDB0EC_PCA_1_STR-AFABE sy-vline
WA_/BIC/CCDB0EC_PCA_1_STR-VERSA sy-vline
WA_/BIC/CCDB0EC_PCA_1_STR-WERKS sy-vline
WA_/BIC/CCDB0EC_PCA_1_STR-REP_MATNR sy-vline
WA_/BIC/CCDB0EC_PCA_1_STR-RSCOPE sy-vline
WA_/BIC/CCDB0EC_PCA_1_STR-RMVCT sy-vline
WA_/BIC/CCDB0EC_PCA_1_STR-VALUETYPE sy-vline
WA_/BIC/CCDB0EC_PCA_1_STR-VALUTYP sy-vline
WA_/BIC/CCDB0EC_PCA_1_STR-RVERS sy-vline
WA_/BIC/CCDB0EC_PCA_1_STR-BALANCE sy-vline
WA_/BIC/CCDB0EC_PCA_1_STR-DEBIT sy-vline
WA_/BIC/CCDB0EC_PCA_1_STR-CREDIT sy-vline
WA_/BIC/CCDB0EC_PCA_1_STR-TURNOVER sy-vline
WA_/BIC/CCDB0EC_PCA_1_STR-CURTYPE sy-vline
WA_/BIC/CCDB0EC_PCA_1_STR-CURRUNIT sy-vline
WA_/BIC/CCDB0EC_PCA_1_STR-QUANTITY sy-vline
WA_/BIC/CCDB0EC_PCA_1_STR-QUANUNIT sy-vline
WA_/BIC/CCDB0EC_PCA_1_STR-UPMOD sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.