ABAP Select data from SAP table /BI0/C_0355 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /BI0/C_0355 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /BI0/C_0355. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /BI0/C_0355 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/BI0/C_0355 TYPE STANDARD TABLE OF /BI0/C_0355,
      WA_/BI0/C_0355 TYPE /BI0/C_0355,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </BI0/C_0355> TYPE /BI0/C_0355.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/BI0/C_0355.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /BI0/C_0355
  INTO TABLE IT_/BI0/C_0355.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /BI0/C_0355
*  INTO TABLE @DATA(IT_/BI0/C_03552).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/BI0/C_0355 INDEX 1 INTO DATA(WA_/BI0/C_03552).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/BI0/C_0355 ASSIGNING </BI0/C_0355>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</BI0/C_0355>-ROCANCEL = 1.
</BI0/C_0355>-EKORG = 1.
</BI0/C_0355>-HERKZ = 1.
</BI0/C_0355>-KUNUM = 1.
</BI0/C_0355>-LIFNUM = 1.
ENDLOOP.

LOOP AT IT_/BI0/C_0355 INTO WA_/BI0/C_0355.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/BI0/C_0355-MATNR, sy-vline,
WA_/BI0/C_0355-MAWERK, sy-vline,
WA_/BI0/C_0355-QMART, sy-vline,
WA_/BI0/C_0355-QMDAT, sy-vline,
WA_/BI0/C_0355-QMNUM, sy-vline,
WA_/BI0/C_0355-SPART, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/BI0/C_0355 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/BI0/C_0355 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/BI0/C_0355 INTO WA_/BI0/C_0355. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/BI0/C_0355_STR,
ROCANCEL TYPE STRING,
EKORG TYPE STRING,
HERKZ TYPE STRING,
KUNUM TYPE STRING,
LIFNUM TYPE STRING,
MATNR TYPE STRING,
MAWERK TYPE STRING,
QMART TYPE STRING,
QMDAT TYPE STRING,
QMNUM TYPE STRING,
SPART TYPE STRING,
VKORG TYPE STRING,
VTWEG TYPE STRING,
BAUTL TYPE STRING,
FECOD TYPE STRING,
FEGRP TYPE STRING,
FEKAT TYPE STRING,
FEQKLAS TYPE STRING,
OTEIL TYPE STRING,
OTGRP TYPE STRING,
OTKAT TYPE STRING,
/BI0/FILLER0022 TYPE STRING,
MNCOD TYPE STRING,
MNGRP TYPE STRING,
MNKAT TYPE STRING,
/BI0/FILLER0026 TYPE STRING,
ZHLMAOF TYPE STRING,
ZHLMASS TYPE STRING,
ZHLMERF TYPE STRING,
KEY_MANUM TYPE STRING,END OF T_EKKO_STR. DATA: WA_/BI0/C_0355_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/BI0/C_0355_STR-ROCANCEL sy-vline
WA_/BI0/C_0355_STR-EKORG sy-vline
WA_/BI0/C_0355_STR-HERKZ sy-vline
WA_/BI0/C_0355_STR-KUNUM sy-vline
WA_/BI0/C_0355_STR-LIFNUM sy-vline
WA_/BI0/C_0355_STR-MATNR sy-vline
WA_/BI0/C_0355_STR-MAWERK sy-vline
WA_/BI0/C_0355_STR-QMART sy-vline
WA_/BI0/C_0355_STR-QMDAT sy-vline
WA_/BI0/C_0355_STR-QMNUM sy-vline
WA_/BI0/C_0355_STR-SPART sy-vline
WA_/BI0/C_0355_STR-VKORG sy-vline
WA_/BI0/C_0355_STR-VTWEG sy-vline
WA_/BI0/C_0355_STR-BAUTL sy-vline
WA_/BI0/C_0355_STR-FECOD sy-vline
WA_/BI0/C_0355_STR-FEGRP sy-vline
WA_/BI0/C_0355_STR-FEKAT sy-vline
WA_/BI0/C_0355_STR-FEQKLAS sy-vline
WA_/BI0/C_0355_STR-OTEIL sy-vline
WA_/BI0/C_0355_STR-OTGRP sy-vline
WA_/BI0/C_0355_STR-OTKAT sy-vline
WA_/BI0/C_0355_STR-/BI0/FILLER0022 sy-vline
WA_/BI0/C_0355_STR-MNCOD sy-vline
WA_/BI0/C_0355_STR-MNGRP sy-vline
WA_/BI0/C_0355_STR-MNKAT sy-vline
WA_/BI0/C_0355_STR-/BI0/FILLER0026 sy-vline
WA_/BI0/C_0355_STR-ZHLMAOF sy-vline
WA_/BI0/C_0355_STR-ZHLMASS sy-vline
WA_/BI0/C_0355_STR-ZHLMERF sy-vline
WA_/BI0/C_0355_STR-KEY_MANUM sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.