ABAP Select data from SAP table /BEV3/CHFIA into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /BEV3/CHFIA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /BEV3/CHFIA. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /BEV3/CHFIA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/BEV3/CHFIA TYPE STANDARD TABLE OF /BEV3/CHFIA,
      WA_/BEV3/CHFIA TYPE /BEV3/CHFIA,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </BEV3/CHFIA> TYPE /BEV3/CHFIA.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/BEV3/CHFIA.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /BEV3/CHFIA
  INTO TABLE IT_/BEV3/CHFIA.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /BEV3/CHFIA
*  INTO TABLE @DATA(IT_/BEV3/CHFIA2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/BEV3/CHFIA INDEX 1 INTO DATA(WA_/BEV3/CHFIA2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/BEV3/CHFIA ASSIGNING </BEV3/CHFIA>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</BEV3/CHFIA>-RCLNT = 1.
</BEV3/CHFIA>-GL_SIRID = 1.
</BEV3/CHFIA>-RLDNR = 1.
</BEV3/CHFIA>-RRCTY = 1.
</BEV3/CHFIA>-RVERS = 1.
ENDLOOP.

LOOP AT IT_/BEV3/CHFIA INTO WA_/BEV3/CHFIA.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/BEV3/CHFIA-RYEAR, sy-vline,
WA_/BEV3/CHFIA-RTCUR, sy-vline,
WA_/BEV3/CHFIA-RUNIT, sy-vline,
WA_/BEV3/CHFIA-DRCRK, sy-vline,
WA_/BEV3/CHFIA-POPER, sy-vline,
WA_/BEV3/CHFIA-DOCCT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/BEV3/CHFIA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/BEV3/CHFIA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/BEV3/CHFIA INTO WA_/BEV3/CHFIA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field RLDNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/BEV3/CHFIA-RLDNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/BEV3/CHFIA-RLDNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RVERS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/BEV3/CHFIA-RVERS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/BEV3/CHFIA-RVERS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field RYEAR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_/BEV3/CHFIA-RYEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/BEV3/CHFIA-RYEAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field RUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/BEV3/CHFIA-RUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/BEV3/CHFIA-RUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field DOCNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/BEV3/CHFIA-DOCNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/BEV3/CHFIA-DOCNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RRKUNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/BEV3/CHFIA-RRKUNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/BEV3/CHFIA-RRKUNNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RRVERTN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/BEV3/CHFIA-RRVERTN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/BEV3/CHFIA-RRVERTN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RACCT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/BEV3/CHFIA-RACCT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/BEV3/CHFIA-RACCT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LOGSYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/BEV3/CHFIA-LOGSYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/BEV3/CHFIA-LOGSYS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SACCT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/BEV3/CHFIA-SACCT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/BEV3/CHFIA-SACCT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field TSL CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_/BEV3/CHFIA-TSL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/BEV3/CHFIA-TSL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field HSL CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_/BEV3/CHFIA-HSL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/BEV3/CHFIA-HSL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field KSL CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_/BEV3/CHFIA-KSL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/BEV3/CHFIA-KSL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field AUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/BEV3/CHFIA-AUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/BEV3/CHFIA-AUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field REFDOCNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/BEV3/CHFIA-REFDOCNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/BEV3/CHFIA-REFDOCNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field REFRYEAR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_/BEV3/CHFIA-REFRYEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/BEV3/CHFIA-REFRYEAR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/BEV3/CHFIA_STR,
RCLNT TYPE STRING,
GL_SIRID TYPE STRING,
RLDNR TYPE STRING,
RRCTY TYPE STRING,
RVERS TYPE STRING,
RYEAR TYPE STRING,
RTCUR TYPE STRING,
RUNIT TYPE STRING,
DRCRK TYPE STRING,
POPER TYPE STRING,
DOCCT TYPE STRING,
DOCNR TYPE STRING,
DOCLN TYPE STRING,
RBUKRS TYPE STRING,
RRKUNNR TYPE STRING,
RRVERTN TYPE STRING,
RRVERTT TYPE STRING,
RRVBEWA TYPE STRING,
RACCT TYPE STRING,
LOGSYS TYPE STRING,
SBUKRS TYPE STRING,
SACCT TYPE STRING,
TSL TYPE STRING,
HSL TYPE STRING,
KSL TYPE STRING,
MSL TYPE STRING,
ASL TYPE STRING,
AUNIT TYPE STRING,
SGTXT TYPE STRING,
DOCTY TYPE STRING,
ACTIV TYPE STRING,
BUDAT TYPE STRING,
WSDAT TYPE STRING,
REFDOCNR TYPE STRING,
REFRYEAR TYPE STRING,
REFDOCLN TYPE STRING,
REFDOCCT TYPE STRING,
REFACTIV TYPE STRING,
CPUDT TYPE STRING,
CPUTM TYPE STRING,
USNAM TYPE STRING,
AWTYP TYPE STRING,
AWORG TYPE STRING,
RBLART TYPE STRING,
RBSCHL TYPE STRING,
WAERS TYPE STRING,
WERTST TYPE STRING,
BLDAT TYPE STRING,
BUZEI TYPE STRING,
KOART TYPE STRING,END OF T_EKKO_STR. DATA: WA_/BEV3/CHFIA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/BEV3/CHFIA_STR-RCLNT sy-vline
WA_/BEV3/CHFIA_STR-GL_SIRID sy-vline
WA_/BEV3/CHFIA_STR-RLDNR sy-vline
WA_/BEV3/CHFIA_STR-RRCTY sy-vline
WA_/BEV3/CHFIA_STR-RVERS sy-vline
WA_/BEV3/CHFIA_STR-RYEAR sy-vline
WA_/BEV3/CHFIA_STR-RTCUR sy-vline
WA_/BEV3/CHFIA_STR-RUNIT sy-vline
WA_/BEV3/CHFIA_STR-DRCRK sy-vline
WA_/BEV3/CHFIA_STR-POPER sy-vline
WA_/BEV3/CHFIA_STR-DOCCT sy-vline
WA_/BEV3/CHFIA_STR-DOCNR sy-vline
WA_/BEV3/CHFIA_STR-DOCLN sy-vline
WA_/BEV3/CHFIA_STR-RBUKRS sy-vline
WA_/BEV3/CHFIA_STR-RRKUNNR sy-vline
WA_/BEV3/CHFIA_STR-RRVERTN sy-vline
WA_/BEV3/CHFIA_STR-RRVERTT sy-vline
WA_/BEV3/CHFIA_STR-RRVBEWA sy-vline
WA_/BEV3/CHFIA_STR-RACCT sy-vline
WA_/BEV3/CHFIA_STR-LOGSYS sy-vline
WA_/BEV3/CHFIA_STR-SBUKRS sy-vline
WA_/BEV3/CHFIA_STR-SACCT sy-vline
WA_/BEV3/CHFIA_STR-TSL sy-vline
WA_/BEV3/CHFIA_STR-HSL sy-vline
WA_/BEV3/CHFIA_STR-KSL sy-vline
WA_/BEV3/CHFIA_STR-MSL sy-vline
WA_/BEV3/CHFIA_STR-ASL sy-vline
WA_/BEV3/CHFIA_STR-AUNIT sy-vline
WA_/BEV3/CHFIA_STR-SGTXT sy-vline
WA_/BEV3/CHFIA_STR-DOCTY sy-vline
WA_/BEV3/CHFIA_STR-ACTIV sy-vline
WA_/BEV3/CHFIA_STR-BUDAT sy-vline
WA_/BEV3/CHFIA_STR-WSDAT sy-vline
WA_/BEV3/CHFIA_STR-REFDOCNR sy-vline
WA_/BEV3/CHFIA_STR-REFRYEAR sy-vline
WA_/BEV3/CHFIA_STR-REFDOCLN sy-vline
WA_/BEV3/CHFIA_STR-REFDOCCT sy-vline
WA_/BEV3/CHFIA_STR-REFACTIV sy-vline
WA_/BEV3/CHFIA_STR-CPUDT sy-vline
WA_/BEV3/CHFIA_STR-CPUTM sy-vline
WA_/BEV3/CHFIA_STR-USNAM sy-vline
WA_/BEV3/CHFIA_STR-AWTYP sy-vline
WA_/BEV3/CHFIA_STR-AWORG sy-vline
WA_/BEV3/CHFIA_STR-RBLART sy-vline
WA_/BEV3/CHFIA_STR-RBSCHL sy-vline
WA_/BEV3/CHFIA_STR-WAERS sy-vline
WA_/BEV3/CHFIA_STR-WERTST sy-vline
WA_/BEV3/CHFIA_STR-BLDAT sy-vline
WA_/BEV3/CHFIA_STR-BUZEI sy-vline
WA_/BEV3/CHFIA_STR-KOART sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.