ABAP Select data from SAP table /BCV/S_SIN_UNIT_TEST_ES_RAW into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /BCV/S_SIN_UNIT_TEST_ES_RAW table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /BCV/S_SIN_UNIT_TEST_ES_RAW. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /BCV/S_SIN_UNIT_TEST_ES_RAW table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/BCV/S_SIN_UNIT_TEST_ES_RAW TYPE STANDARD TABLE OF /BCV/S_SIN_UNIT_TEST_ES_RAW,
      WA_/BCV/S_SIN_UNIT_TEST_ES_RAW TYPE /BCV/S_SIN_UNIT_TEST_ES_RAW,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </BCV/S_SIN_UNIT_TEST_ES_RAW> TYPE /BCV/S_SIN_UNIT_TEST_ES_RAW.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/BCV/S_SIN_UNIT_TEST_ES_RAW.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /BCV/S_SIN_UNIT_TEST_ES_RAW
  INTO TABLE IT_/BCV/S_SIN_UNIT_TEST_ES_RAW.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /BCV/S_SIN_UNIT_TEST_ES_RAW
*  INTO TABLE @DATA(IT_/BCV/S_SIN_UNIT_TEST_ES_RAW2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/BCV/S_SIN_UNIT_TEST_ES_RAW INDEX 1 INTO DATA(WA_/BCV/S_SIN_UNIT_TEST_ES_RAW2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/BCV/S_SIN_UNIT_TEST_ES_RAW ASSIGNING </BCV/S_SIN_UNIT_TEST_ES_RAW>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</BCV/S_SIN_UNIT_TEST_ES_RAW>-ACC_ID_EXTERNAL = 1.
</BCV/S_SIN_UNIT_TEST_ES_RAW>-AENAM = 1.
</BCV/S_SIN_UNIT_TEST_ES_RAW>-ATTYP = 1.
</BCV/S_SIN_UNIT_TEST_ES_RAW>-BEGRU = 1.
</BCV/S_SIN_UNIT_TEST_ES_RAW>-BEGRU1 = 1.
ENDLOOP.

LOOP AT IT_/BCV/S_SIN_UNIT_TEST_ES_RAW INTO WA_/BCV/S_SIN_UNIT_TEST_ES_RAW.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/BCV/S_SIN_UNIT_TEST_ES_RAW-BISMT, sy-vline,
WA_/BCV/S_SIN_UNIT_TEST_ES_RAW-BRGEW, sy-vline,
WA_/BCV/S_SIN_UNIT_TEST_ES_RAW-CADKZ, sy-vline,
WA_/BCV/S_SIN_UNIT_TEST_ES_RAW-CHANGED_BY, sy-vline,
WA_/BCV/S_SIN_UNIT_TEST_ES_RAW-CHANGED_ON, sy-vline,
WA_/BCV/S_SIN_UNIT_TEST_ES_RAW-EAN11, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/BCV/S_SIN_UNIT_TEST_ES_RAW you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/BCV/S_SIN_UNIT_TEST_ES_RAW TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/BCV/S_SIN_UNIT_TEST_ES_RAW INTO WA_/BCV/S_SIN_UNIT_TEST_ES_RAW. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/BCV/S_SIN_UNIT_TEST_ES_RAW_STR,
ACC_ID_EXTERNAL TYPE STRING,
AENAM TYPE STRING,
ATTYP TYPE STRING,
BEGRU TYPE STRING,
BEGRU1 TYPE STRING,
BISMT TYPE STRING,
BRGEW TYPE STRING,
CADKZ TYPE STRING,
CHANGED_BY TYPE STRING,
CHANGED_ON TYPE STRING,
EAN11 TYPE STRING,
ERNAM TYPE STRING,
ERSDA TYPE STRING,
EXTWG TYPE STRING,
GEWEI TYPE STRING,
GROES TYPE STRING,
HAZMAT TYPE STRING,
HNDLCODE TYPE STRING,
IHIVI TYPE STRING,
ILOOS TYPE STRING,
KZUMW TYPE STRING,
LABOR TYPE STRING,
LAEDA TYPE STRING,
LVORM TYPE STRING,
MAGRV TYPE STRING,
MAKTX TYPE STRING,
MATKL TYPE STRING,
MATNR TYPE STRING,
MEINS TYPE STRING,
MSTAE TYPE STRING,
MSTDE TYPE STRING,
MTART TYPE STRING,
MTBEZ TYPE STRING,
MTPOS_MARA TYPE STRING,
NORMT TYPE STRING,
NTGEW TYPE STRING,
NUMTP TYPE STRING,
PRDHA TYPE STRING,
PROFL TYPE STRING,
SATNR TYPE STRING,
SPART TYPE STRING,
VOLEH TYPE STRING,
VOLUM TYPE STRING,
WGBEZ TYPE STRING,
WHMATGR TYPE STRING,
WHSTC TYPE STRING,
WRKST TYPE STRING,
ZEIAR TYPE STRING,
ZEINR TYPE STRING,
ZEIVR TYPE STRING,END OF T_EKKO_STR. DATA: WA_/BCV/S_SIN_UNIT_TEST_ES_RAW_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/BCV/S_SIN_UNIT_TEST_ES_RAW_STR-ACC_ID_EXTERNAL sy-vline
WA_/BCV/S_SIN_UNIT_TEST_ES_RAW_STR-AENAM sy-vline
WA_/BCV/S_SIN_UNIT_TEST_ES_RAW_STR-ATTYP sy-vline
WA_/BCV/S_SIN_UNIT_TEST_ES_RAW_STR-BEGRU sy-vline
WA_/BCV/S_SIN_UNIT_TEST_ES_RAW_STR-BEGRU1 sy-vline
WA_/BCV/S_SIN_UNIT_TEST_ES_RAW_STR-BISMT sy-vline
WA_/BCV/S_SIN_UNIT_TEST_ES_RAW_STR-BRGEW sy-vline
WA_/BCV/S_SIN_UNIT_TEST_ES_RAW_STR-CADKZ sy-vline
WA_/BCV/S_SIN_UNIT_TEST_ES_RAW_STR-CHANGED_BY sy-vline
WA_/BCV/S_SIN_UNIT_TEST_ES_RAW_STR-CHANGED_ON sy-vline
WA_/BCV/S_SIN_UNIT_TEST_ES_RAW_STR-EAN11 sy-vline
WA_/BCV/S_SIN_UNIT_TEST_ES_RAW_STR-ERNAM sy-vline
WA_/BCV/S_SIN_UNIT_TEST_ES_RAW_STR-ERSDA sy-vline
WA_/BCV/S_SIN_UNIT_TEST_ES_RAW_STR-EXTWG sy-vline
WA_/BCV/S_SIN_UNIT_TEST_ES_RAW_STR-GEWEI sy-vline
WA_/BCV/S_SIN_UNIT_TEST_ES_RAW_STR-GROES sy-vline
WA_/BCV/S_SIN_UNIT_TEST_ES_RAW_STR-HAZMAT sy-vline
WA_/BCV/S_SIN_UNIT_TEST_ES_RAW_STR-HNDLCODE sy-vline
WA_/BCV/S_SIN_UNIT_TEST_ES_RAW_STR-IHIVI sy-vline
WA_/BCV/S_SIN_UNIT_TEST_ES_RAW_STR-ILOOS sy-vline
WA_/BCV/S_SIN_UNIT_TEST_ES_RAW_STR-KZUMW sy-vline
WA_/BCV/S_SIN_UNIT_TEST_ES_RAW_STR-LABOR sy-vline
WA_/BCV/S_SIN_UNIT_TEST_ES_RAW_STR-LAEDA sy-vline
WA_/BCV/S_SIN_UNIT_TEST_ES_RAW_STR-LVORM sy-vline
WA_/BCV/S_SIN_UNIT_TEST_ES_RAW_STR-MAGRV sy-vline
WA_/BCV/S_SIN_UNIT_TEST_ES_RAW_STR-MAKTX sy-vline
WA_/BCV/S_SIN_UNIT_TEST_ES_RAW_STR-MATKL sy-vline
WA_/BCV/S_SIN_UNIT_TEST_ES_RAW_STR-MATNR sy-vline
WA_/BCV/S_SIN_UNIT_TEST_ES_RAW_STR-MEINS sy-vline
WA_/BCV/S_SIN_UNIT_TEST_ES_RAW_STR-MSTAE sy-vline
WA_/BCV/S_SIN_UNIT_TEST_ES_RAW_STR-MSTDE sy-vline
WA_/BCV/S_SIN_UNIT_TEST_ES_RAW_STR-MTART sy-vline
WA_/BCV/S_SIN_UNIT_TEST_ES_RAW_STR-MTBEZ sy-vline
WA_/BCV/S_SIN_UNIT_TEST_ES_RAW_STR-MTPOS_MARA sy-vline
WA_/BCV/S_SIN_UNIT_TEST_ES_RAW_STR-NORMT sy-vline
WA_/BCV/S_SIN_UNIT_TEST_ES_RAW_STR-NTGEW sy-vline
WA_/BCV/S_SIN_UNIT_TEST_ES_RAW_STR-NUMTP sy-vline
WA_/BCV/S_SIN_UNIT_TEST_ES_RAW_STR-PRDHA sy-vline
WA_/BCV/S_SIN_UNIT_TEST_ES_RAW_STR-PROFL sy-vline
WA_/BCV/S_SIN_UNIT_TEST_ES_RAW_STR-SATNR sy-vline
WA_/BCV/S_SIN_UNIT_TEST_ES_RAW_STR-SPART sy-vline
WA_/BCV/S_SIN_UNIT_TEST_ES_RAW_STR-VOLEH sy-vline
WA_/BCV/S_SIN_UNIT_TEST_ES_RAW_STR-VOLUM sy-vline
WA_/BCV/S_SIN_UNIT_TEST_ES_RAW_STR-WGBEZ sy-vline
WA_/BCV/S_SIN_UNIT_TEST_ES_RAW_STR-WHMATGR sy-vline
WA_/BCV/S_SIN_UNIT_TEST_ES_RAW_STR-WHSTC sy-vline
WA_/BCV/S_SIN_UNIT_TEST_ES_RAW_STR-WRKST sy-vline
WA_/BCV/S_SIN_UNIT_TEST_ES_RAW_STR-ZEIAR sy-vline
WA_/BCV/S_SIN_UNIT_TEST_ES_RAW_STR-ZEINR sy-vline
WA_/BCV/S_SIN_UNIT_TEST_ES_RAW_STR-ZEIVR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.