ABAP Select data from SAP table /AIF/S_CFUNC_WITH_PARA into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /AIF/S_CFUNC_WITH_PARA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /AIF/S_CFUNC_WITH_PARA. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /AIF/S_CFUNC_WITH_PARA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/AIF/S_CFUNC_WITH_PARA TYPE STANDARD TABLE OF /AIF/S_CFUNC_WITH_PARA,
      WA_/AIF/S_CFUNC_WITH_PARA TYPE /AIF/S_CFUNC_WITH_PARA,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </AIF/S_CFUNC_WITH_PARA> TYPE /AIF/S_CFUNC_WITH_PARA.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/AIF/S_CFUNC_WITH_PARA.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /AIF/S_CFUNC_WITH_PARA
  INTO TABLE IT_/AIF/S_CFUNC_WITH_PARA.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /AIF/S_CFUNC_WITH_PARA
*  INTO TABLE @DATA(IT_/AIF/S_CFUNC_WITH_PARA2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/AIF/S_CFUNC_WITH_PARA INDEX 1 INTO DATA(WA_/AIF/S_CFUNC_WITH_PARA2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/AIF/S_CFUNC_WITH_PARA ASSIGNING </AIF/S_CFUNC_WITH_PARA>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</AIF/S_CFUNC_WITH_PARA>-NS = 1.
</AIF/S_CFUNC_WITH_PARA>-IFNAME = 1.
</AIF/S_CFUNC_WITH_PARA>-IFVER = 1.
</AIF/S_CFUNC_WITH_PARA>-IDFUNC = 1.
</AIF/S_CFUNC_WITH_PARA>-AUTHUSER = 1.
ENDLOOP.

LOOP AT IT_/AIF/S_CFUNC_WITH_PARA INTO WA_/AIF/S_CFUNC_WITH_PARA.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/AIF/S_CFUNC_WITH_PARA-FUNCICON, sy-vline,
WA_/AIF/S_CFUNC_WITH_PARA-MSGID, sy-vline,
WA_/AIF/S_CFUNC_WITH_PARA-MSGNO, sy-vline,
WA_/AIF/S_CFUNC_WITH_PARA-CREATEUSER, sy-vline,
WA_/AIF/S_CFUNC_WITH_PARA-CREATEDATE, sy-vline,
WA_/AIF/S_CFUNC_WITH_PARA-SKIPFSCREEN, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/AIF/S_CFUNC_WITH_PARA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/AIF/S_CFUNC_WITH_PARA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/AIF/S_CFUNC_WITH_PARA INTO WA_/AIF/S_CFUNC_WITH_PARA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ISOLA, internal->external for field SPRSL CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_/AIF/S_CFUNC_WITH_PARA-SPRSL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/AIF/S_CFUNC_WITH_PARA-SPRSL.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/AIF/S_CFUNC_WITH_PARA_STR,
NS TYPE STRING,
IFNAME TYPE STRING,
IFVER TYPE STRING,
IDFUNC TYPE STRING,
AUTHUSER TYPE STRING,
FUNCICON TYPE STRING,
MSGID TYPE STRING,
MSGNO TYPE STRING,
CREATEUSER TYPE STRING,
CREATEDATE TYPE STRING,
SKIPFSCREEN TYPE STRING,
INNEWSESSION TYPE STRING,
CFUNC_MODE TYPE STRING,
CFUNC_NAME TYPE STRING,
DYPNO TYPE STRING,
VISIBILITY TYPE STRING,
SCOPE TYPE STRING,
IMAGESOURCE TYPE STRING,
SPRSL TYPE STRING,
TEXT TYPE STRING,
TOOLTIP TYPE STRING,
SEM_OBJ TYPE STRING,
SEM_ACT TYPE STRING,
PARAMETERS TYPE STRING,END OF T_EKKO_STR. DATA: WA_/AIF/S_CFUNC_WITH_PARA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/AIF/S_CFUNC_WITH_PARA_STR-NS sy-vline
WA_/AIF/S_CFUNC_WITH_PARA_STR-IFNAME sy-vline
WA_/AIF/S_CFUNC_WITH_PARA_STR-IFVER sy-vline
WA_/AIF/S_CFUNC_WITH_PARA_STR-IDFUNC sy-vline
WA_/AIF/S_CFUNC_WITH_PARA_STR-AUTHUSER sy-vline
WA_/AIF/S_CFUNC_WITH_PARA_STR-FUNCICON sy-vline
WA_/AIF/S_CFUNC_WITH_PARA_STR-MSGID sy-vline
WA_/AIF/S_CFUNC_WITH_PARA_STR-MSGNO sy-vline
WA_/AIF/S_CFUNC_WITH_PARA_STR-CREATEUSER sy-vline
WA_/AIF/S_CFUNC_WITH_PARA_STR-CREATEDATE sy-vline
WA_/AIF/S_CFUNC_WITH_PARA_STR-SKIPFSCREEN sy-vline
WA_/AIF/S_CFUNC_WITH_PARA_STR-INNEWSESSION sy-vline
WA_/AIF/S_CFUNC_WITH_PARA_STR-CFUNC_MODE sy-vline
WA_/AIF/S_CFUNC_WITH_PARA_STR-CFUNC_NAME sy-vline
WA_/AIF/S_CFUNC_WITH_PARA_STR-DYPNO sy-vline
WA_/AIF/S_CFUNC_WITH_PARA_STR-VISIBILITY sy-vline
WA_/AIF/S_CFUNC_WITH_PARA_STR-SCOPE sy-vline
WA_/AIF/S_CFUNC_WITH_PARA_STR-IMAGESOURCE sy-vline
WA_/AIF/S_CFUNC_WITH_PARA_STR-SPRSL sy-vline
WA_/AIF/S_CFUNC_WITH_PARA_STR-TEXT sy-vline
WA_/AIF/S_CFUNC_WITH_PARA_STR-TOOLTIP sy-vline
WA_/AIF/S_CFUNC_WITH_PARA_STR-SEM_OBJ sy-vline
WA_/AIF/S_CFUNC_WITH_PARA_STR-SEM_ACT sy-vline
WA_/AIF/S_CFUNC_WITH_PARA_STR-PARAMETERS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.