ABAP Select data from SAP table /ACCGO/UIS_S_ANDT_BL into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /ACCGO/UIS_S_ANDT_BL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /ACCGO/UIS_S_ANDT_BL. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /ACCGO/UIS_S_ANDT_BL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/ACCGO/UIS_S_ANDT_BL TYPE STANDARD TABLE OF /ACCGO/UIS_S_ANDT_BL,
      WA_/ACCGO/UIS_S_ANDT_BL TYPE /ACCGO/UIS_S_ANDT_BL,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </ACCGO/UIS_S_ANDT_BL> TYPE /ACCGO/UIS_S_ANDT_BL.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/ACCGO/UIS_S_ANDT_BL.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /ACCGO/UIS_S_ANDT_BL
  INTO TABLE IT_/ACCGO/UIS_S_ANDT_BL.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /ACCGO/UIS_S_ANDT_BL
*  INTO TABLE @DATA(IT_/ACCGO/UIS_S_ANDT_BL2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/ACCGO/UIS_S_ANDT_BL INDEX 1 INTO DATA(WA_/ACCGO/UIS_S_ANDT_BL2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/ACCGO/UIS_S_ANDT_BL ASSIGNING </ACCGO/UIS_S_ANDT_BL>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</ACCGO/UIS_S_ANDT_BL>-MANDT = 1.
</ACCGO/UIS_S_ANDT_BL>-UIS_AN_KEY = 1.
</ACCGO/UIS_S_ANDT_BL>-PARENT_KEY = 1.
</ACCGO/UIS_S_ANDT_BL>-CERT_CATEGORY = 1.
</ACCGO/UIS_S_ANDT_BL>-CERT_ID = 1.
ENDLOOP.

LOOP AT IT_/ACCGO/UIS_S_ANDT_BL INTO WA_/ACCGO/UIS_S_ANDT_BL.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/ACCGO/UIS_S_ANDT_BL-ANALYSIS_TYPE, sy-vline,
WA_/ACCGO/UIS_S_ANDT_BL-ANALYSIS_CODE, sy-vline,
WA_/ACCGO/UIS_S_ANDT_BL-AGENCY, sy-vline,
WA_/ACCGO/UIS_S_ANDT_BL-PHY_SMPL_ID, sy-vline,
WA_/ACCGO/UIS_S_ANDT_BL-GRADE, sy-vline,
WA_/ACCGO/UIS_S_ANDT_BL-AN_RESULT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/ACCGO/UIS_S_ANDT_BL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/ACCGO/UIS_S_ANDT_BL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/ACCGO/UIS_S_ANDT_BL INTO WA_/ACCGO/UIS_S_ANDT_BL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit TSTLC, internal->external for field CREATED_ON CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_/ACCGO/UIS_S_ANDT_BL-CREATED_ON IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/ACCGO/UIS_S_ANDT_BL-CREATED_ON.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTLC, internal->external for field CHANGED_ON CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_/ACCGO/UIS_S_ANDT_BL-CHANGED_ON IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/ACCGO/UIS_S_ANDT_BL-CHANGED_ON.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/ACCGO/UIS_S_ANDT_BL_STR,
MANDT TYPE STRING,
UIS_AN_KEY TYPE STRING,
PARENT_KEY TYPE STRING,
CERT_CATEGORY TYPE STRING,
CERT_ID TYPE STRING,
ANALYSIS_TYPE TYPE STRING,
ANALYSIS_CODE TYPE STRING,
AGENCY TYPE STRING,
PHY_SMPL_ID TYPE STRING,
GRADE TYPE STRING,
AN_RESULT TYPE STRING,
INSPCT_INSTR TYPE STRING,
COMMENTS TYPE STRING,
INSPECTED_BY TYPE STRING,
INSPECTION_DATE TYPE STRING,
INSPECTION_TIME TYPE STRING,
LOGICALLY_DELETED TYPE STRING,
CREATED_BY TYPE STRING,
CREATED_ON TYPE STRING,
CHANGED_BY TYPE STRING,
CHANGED_ON TYPE STRING,
UPD_IND TYPE STRING,
UIS_OBJ_KEY TYPE STRING,
VALID_STATUS TYPE STRING,
APPLOG_VER TYPE STRING,END OF T_EKKO_STR. DATA: WA_/ACCGO/UIS_S_ANDT_BL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/ACCGO/UIS_S_ANDT_BL_STR-MANDT sy-vline
WA_/ACCGO/UIS_S_ANDT_BL_STR-UIS_AN_KEY sy-vline
WA_/ACCGO/UIS_S_ANDT_BL_STR-PARENT_KEY sy-vline
WA_/ACCGO/UIS_S_ANDT_BL_STR-CERT_CATEGORY sy-vline
WA_/ACCGO/UIS_S_ANDT_BL_STR-CERT_ID sy-vline
WA_/ACCGO/UIS_S_ANDT_BL_STR-ANALYSIS_TYPE sy-vline
WA_/ACCGO/UIS_S_ANDT_BL_STR-ANALYSIS_CODE sy-vline
WA_/ACCGO/UIS_S_ANDT_BL_STR-AGENCY sy-vline
WA_/ACCGO/UIS_S_ANDT_BL_STR-PHY_SMPL_ID sy-vline
WA_/ACCGO/UIS_S_ANDT_BL_STR-GRADE sy-vline
WA_/ACCGO/UIS_S_ANDT_BL_STR-AN_RESULT sy-vline
WA_/ACCGO/UIS_S_ANDT_BL_STR-INSPCT_INSTR sy-vline
WA_/ACCGO/UIS_S_ANDT_BL_STR-COMMENTS sy-vline
WA_/ACCGO/UIS_S_ANDT_BL_STR-INSPECTED_BY sy-vline
WA_/ACCGO/UIS_S_ANDT_BL_STR-INSPECTION_DATE sy-vline
WA_/ACCGO/UIS_S_ANDT_BL_STR-INSPECTION_TIME sy-vline
WA_/ACCGO/UIS_S_ANDT_BL_STR-LOGICALLY_DELETED sy-vline
WA_/ACCGO/UIS_S_ANDT_BL_STR-CREATED_BY sy-vline
WA_/ACCGO/UIS_S_ANDT_BL_STR-CREATED_ON sy-vline
WA_/ACCGO/UIS_S_ANDT_BL_STR-CHANGED_BY sy-vline
WA_/ACCGO/UIS_S_ANDT_BL_STR-CHANGED_ON sy-vline
WA_/ACCGO/UIS_S_ANDT_BL_STR-UPD_IND sy-vline
WA_/ACCGO/UIS_S_ANDT_BL_STR-UIS_OBJ_KEY sy-vline
WA_/ACCGO/UIS_S_ANDT_BL_STR-VALID_STATUS sy-vline
WA_/ACCGO/UIS_S_ANDT_BL_STR-APPLOG_VER sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.