ABAP Select data from SAP table /1ISRWP/800H0204 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /1ISRWP/800H0204 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /1ISRWP/800H0204. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /1ISRWP/800H0204 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/1ISRWP/800H0204 TYPE STANDARD TABLE OF /1ISRWP/800H0204,
      WA_/1ISRWP/800H0204 TYPE /1ISRWP/800H0204,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </1ISRWP/800H0204> TYPE /1ISRWP/800H0204.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/1ISRWP/800H0204.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /1ISRWP/800H0204
  INTO TABLE IT_/1ISRWP/800H0204.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /1ISRWP/800H0204
*  INTO TABLE @DATA(IT_/1ISRWP/800H02042).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/1ISRWP/800H0204 INDEX 1 INTO DATA(WA_/1ISRWP/800H02042).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/1ISRWP/800H0204 ASSIGNING </1ISRWP/800H0204>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</1ISRWP/800H0204>-PLHVS = 1.
</1ISRWP/800H0204>-EKORG = 1.
</1ISRWP/800H0204>-VKORG = 1.
</1ISRWP/800H0204>-VTWEG = 1.
</1ISRWP/800H0204>-WGRU2 = 1.
ENDLOOP.

LOOP AT IT_/1ISRWP/800H0204 INTO WA_/1ISRWP/800H0204.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/1ISRWP/800H0204-RELEF1, sy-vline,
WA_/1ISRWP/800H0204-RELEF2, sy-vline,
WA_/1ISRWP/800H0204-RELEF3, sy-vline,
WA_/1ISRWP/800H0204-PRODF1, sy-vline,
WA_/1ISRWP/800H0204-PRODF2, sy-vline,
WA_/1ISRWP/800H0204-PRODF3, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/1ISRWP/800H0204 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/1ISRWP/800H0204 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/1ISRWP/800H0204 INTO WA_/1ISRWP/800H0204. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field PLHVS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/1ISRWP/800H0204-PLHVS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/1ISRWP/800H0204-PLHVS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PLMHT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/1ISRWP/800H0204-PLMHT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/1ISRWP/800H0204-PLMHT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field BASME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/1ISRWP/800H0204-BASME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/1ISRWP/800H0204-BASME.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/1ISRWP/800H0204_STR,
PLHVS TYPE STRING,
EKORG TYPE STRING,
VKORG TYPE STRING,
VTWEG TYPE STRING,
WGRU2 TYPE STRING,
RELEF1 TYPE STRING,
RELEF2 TYPE STRING,
RELEF3 TYPE STRING,
PRODF1 TYPE STRING,
PRODF2 TYPE STRING,
PRODF3 TYPE STRING,
PLMHT TYPE STRING,
SPRED_3 TYPE STRING,
SPRED_7 TYPE STRING,
FLGBASME TYPE STRING,
BASME TYPE STRING,
FACTOR TYPE STRING,END OF T_EKKO_STR. DATA: WA_/1ISRWP/800H0204_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/1ISRWP/800H0204_STR-PLHVS sy-vline
WA_/1ISRWP/800H0204_STR-EKORG sy-vline
WA_/1ISRWP/800H0204_STR-VKORG sy-vline
WA_/1ISRWP/800H0204_STR-VTWEG sy-vline
WA_/1ISRWP/800H0204_STR-WGRU2 sy-vline
WA_/1ISRWP/800H0204_STR-RELEF1 sy-vline
WA_/1ISRWP/800H0204_STR-RELEF2 sy-vline
WA_/1ISRWP/800H0204_STR-RELEF3 sy-vline
WA_/1ISRWP/800H0204_STR-PRODF1 sy-vline
WA_/1ISRWP/800H0204_STR-PRODF2 sy-vline
WA_/1ISRWP/800H0204_STR-PRODF3 sy-vline
WA_/1ISRWP/800H0204_STR-PLMHT sy-vline
WA_/1ISRWP/800H0204_STR-SPRED_3 sy-vline
WA_/1ISRWP/800H0204_STR-SPRED_7 sy-vline
WA_/1ISRWP/800H0204_STR-FLGBASME sy-vline
WA_/1ISRWP/800H0204_STR-BASME sy-vline
WA_/1ISRWP/800H0204_STR-FACTOR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.